How to properly remove imported bearings

Home>Bearing knowledge>How to properly remove imported bearings
/*728*90 created on 2018/5/16*/ var cpro_id = "u3440131";

How to properly remove imported bearings

Source: Bearing network time: 2014-02-20

/*250*250 was created on 2017/12/25*/ var cpro_id = 'u3171089';
In the process of using imported bearings; timing eradication is very important.
How to properly remove imported bearings:
1. When the imported bearings are removed and viewed, the appearances should be recorded by shooting.
2, other; to recognize the amount of lubricant remaining and sample the lubricant; then remove the bearing.
3. The removal of the bearing is divided into rough washing and fine washing; and the metal mesh frame can be placed on the bottom of the used container.
1) When rough washing; remove the grease or adhesive with a brush at the top of the oil. If you change the bearing in the oil at this moment, be careful to damage the rolling surface due to foreign matter.
2), during fine washing; gradually change the bearing in the oil; must be carefully carried out.
4, the general use of the scavenger is neutral non-aqueous diesel or kerosene; sometimes also use warm lye, etc. as needed. No matter which type of scavenger is used; always filter and keep clean.
5, after eradication; immediately apply anti-rust oil or anti-rust grease on the imported bearings

Recommend to friends comments close window

Bearing related knowledge
How to remove the clearance of the imported bearing in the motor, the clearance of the vibrating screen bearing, the disassembly and protection of the hub bearing seal layout, and the analysis of the comparison test at home and abroad (1)
Linear rolling bearing features


This article links to http://
Please indicate China Bearing Network http://

Previous:Automobile Protection Knowledge----Generator Bearings Next: Rolling bearings with good grease are still good with oil

Saliva Collection Kit

This product is used in collecting high-quality DNA/RNA samples from saliva and can be used in various biological experiments such as enzymatic hydrolysis, PCR, and next-generation sequencing. It is widely used for the collection and preservation of specimens in hospitals, scientific research institutions, and families. The collection process is easy and painless, and will not cause any damage or discomfort to the human body.

Features
♦ Contactless sample collection, less risk for healthcare workers.
♦ Suitable for all kinds of people, easy method to collect samples.
♦ Easy to use, non-invasive collection.
♦ Use medical PP material.
The Saliva Collection Kit is a complete kit made out of 100% polypropylene.
The funnel has been engineered to be intuitively easy to use and specifically designed to reduce user self-collection error by preventing flowback.
When saliva is captured in a sterile container, COVID-19 is stable at room temperature for up to seven days without the need for expensive reagents.


Saliva Collection,Saliva Collector,Spit Collector,Saliva Collection Device,Saliva Sample Collector

Yong Yue Medical Technology(Kunshan) Co.,Ltd , https://www.yonyue.com