Worm gear reducer heat common causes and general solutions

What should we do when we encounter worm gear reducer fever? What are the common causes of worm gear reducer heating?
1, the conveyor belt may not be fixed, resulting in increased worm friction, serious internal shaft wear, solid heat serious, check if the above reasons are not fixed and fixed, there is friction on the lubricant, serious replacement parts.
2. Check if the oil path is damaged, if there is a problem with the seal, or if the oil is less, the oil mark is damaged. If this is the case, then you must replace the oil plug, inject the oil to the specified parameters, and seal the sealant.
3, check whether foreign matter invades the worm gear deformation caused by damage, then open the case, use a powerful vacuum cleaner to remove debris, objects can also be removed directly with a large tool, damaged place oil lubrication.
4, may also be worm gear, worm gear does not fit, shaft clearance is too large, less lubricant, solution: polished gear surface to make it fit, according to the instructions to add the right amount of oil, engine inspection is normal.
5, long running time, resulting in the aging of the circuit components, replace the circuit components of the problem, the appropriate control of the use of time, continuous operation after a period of time should let the machine stop running.