Membrane pump installation Instructions First, the diaphragm pump to be installed before you understand: 1, suction pipe and discharge pipe diameter configuration: (1) suction pipe diameter not less than the pump inlet port diameter, such as the delivery of high viscosity fluid, inhalation The pipe diameter is preferably greater than the pump inlet diameter. Suction piping on the inlet side must be durable and free of wrinkles to create a high vacuum condition. (2) The diameter of the outlet pipe should be at least equal to the outlet diameter or slightly larger to reduce the friction loss. All piping and fittings must be leak-tight or pump self-priming will be reduced. 2, the location of the diaphragm pump installation, height, piping layout, gas supply and other matters: Pneumatic diaphragm pump installation: If ignore the installation details, a long period of careful planning, research and selection will still result in poor pumping effect and affect the pump The service life. (1) Location: Noise, safety and other logic often require that the equipment be installed. Parallel installation with conflicting requirements may result in blockage in the area of ​​use, affecting the installation of other pumps. (2) Use: First, the location of the pump must be easy to use, so that maintenance personnel will facilitate routine inspection and commissioning. (3) Air supply: Each pump should have a vent pipe, and the vent pipe should be able to provide enough air to achieve the desired pump flow. Air pressure according to different pumping needs, but not more than 7BAR. (125PSI) (4) Installation height: Please consider the self-priming ability of the pump to avoid the problem of self-priming reduction. (5) Piping: The pump position can not be finalized until after considering each possible location of the piping problem. 3, other installation instructions: The best installation should be selected in a shortest and most direct import and export pipeline connections. Should try to avoid the extra elbow and pipe fittings facilities. The pump body should be able to support all piping independently. Also, the piping should be ordered to avoid stress on the pump piping. Active hoses can be installed to eliminate stress from the pump's natural movement back and forth. To attach the pump body to a fixed base, placing a cushion between the pump body and the base will help reduce body vibration. If a pneumatic diaphragm pump is to be used for pumping fine media, verify that all pipe connections must be hermetically sealed and that the self-priming lift be within the pump's capacity. To stop the pump from operating in an emergency, simply turn off the "cut-off" valve mounted on the trachea. A suitable functional valve will stop the pump air supply, thus preventing the output. The "deadline" valve should be installed in the area not far from the pump in case of emergencies. Second, the pneumatic diaphragm pump specific installation process: 1, pneumatic diaphragm pump installation and start: The diaphragm pump placed as close to the product where possible, the shortest intake pipe line, reduce the number of configuration components, do not reduce the pipe size. To extend the life of the diaphragm, keep the pump as close as possible to the fluid being pumped and require a slow pressure adjustment mechanism to extend the diaphragm life at inlet pressures in excess of 10 feet (3 meters). If hard piping is installed, use a short hose between the pump and the piping. Hoses can slow pipe vibrations and distortions, and a surge tank is recommended to further reduce the pulses in the fluid. 2, to the diaphragm pump gas supply: metal diaphragm pump supply pressure shall not exceed 125PSI (8.6BAR), plastic pump supply pressure shall not exceed 100PSI (6.9BAR). Connect the air inlet of the pump to the air supply with enough capacity and pressure to meet the design requirements. If the air supply line is a hard pipe, connect a short hose between the pump and the pipe to reduce distortion. In addition to the air inlet cap, the air intake pipe, the pressure regulator filter weight must also be supported by some means. Failure to support the pipe may damage the pump. Pressure regulators must be installed to ensure that the supply pressure does not exceed the specified range. 3, the diaphragm pump before the operation check: diaphragm pump work, prosecute all ** fixtures to prevent relaxation, tighten the loose place to avoid leakage, with the pump attached to the card described in the method of fixing. 4, diaphragm pump intake and start: start, the air valve open about 1/2 to 3/4 laps. After the pump is started, open the air valve to increase air flow to achieve the required flow rate. 5, pneumatic diaphragm pump exhaust: If the diaphragm is broken, the extracted liquid or gas will enter the pump air port, was discharged into the atmosphere, when the extraction of dangerous or toxic substances, the need to pipe to the appropriate place for safe handling . If the pump sink into the liquid work, the gas to be discharged from the liquid level, the exhaust pipe can not be less than 1 "(2.45CM) .Decreasing the exhaust pipe size will limit the gas flow, reducing pump usage .When the material level is high In the pump, the discharge outlet should be at a higher place to prevent siphon phenomenon.Under a certain temperature and humidity, the discharge of gas may freeze up, the use of gas drying can eliminate most of these problems. 6, pneumatic diaphragm Pump after use: If used to transport easily curable materials, to prevent damage to the pump, thoroughly clean the pump after each use (after use, the product left in the pump has dried or stuck to the pump, so Will cause problems with diaphragm and valve before next start-up.) At freezing temperatures, the pump must be drained dry after any use. 3. Notes on Valve Lubrication: Air Distribution Valves and Guided Valves are designed with no oil, which is the ideal working condition.In some cases, such as personal hobby or air quality is very poor, but also on the supply of compressed air Run , Compressed air supply system is properly lubricated, the pump air system industry can work with appropriate lubrication requires the use of an air line lubricator set to pump the air every 20SCFM deliver a drop of non-detergent oil, you can check the pump Performance curve open quantitative.Pneumatic diaphragm pump feed pipe generally do not install the valve, the direct election Diaphragm and diaphragm pump on the tube, pay attention to the feeding tube to have a certain intensity, or tube will be deflated work, affecting the feed Generally in the discharge pipe plus a valve to see the scene conditions, is installed manual valve or automatic valve.Pipeline, valve selection should pay attention to the material properties (such as pH, corrosivity, etc.) to match. General to install triple (pressure regulating, drainage, lubrication), the general import pump without lubricating oil. Ball valve, flow control valve (optional). If the demanding occasions also require the installation of regulators, pressure gauges, leak detection Instrument, etc .. Such as the installation of solenoid valves, metering controllers, but also the diaphragm pump into a metering pump, for remote control feeding.
LED Downlight
LED downlight ,with LEDER technology's smooth design is an enhanced and modernized retrofit light. Using a secure and reliable installation method, this light is compatible with housing that features interior spring bracket holders.
Built with steady dimmable technology, and compatible with most modern dimmers including wireless systems. LED Downlight is an especially good choice for anyone looking for a lamp which is elegant in an understated way. If you want an LED Downlight that discreetly keeps itself out of the way, yet looks great once you actually pay attention to it, you have definitely come to the right place. This LED Downlight will do its job very well.
Features:
• Grace design
• Easy to install
• Excellent power saving
• Suitable for operation at low temperature
• Color temperature :3000K-6000K
• Body color can be customized as RAL Code
• Type of protection: IP20 / IP65 (Some models)
• Warranty: 3 ~ 5 years
Our Downlight is compatible with dimmer switches, so you can always get just the right light for dinner or game night. Bring effortless light into your kitchen, bathroom, or living room with this.
We have rich production experience in lighting.Except LED Downlight , we also offered other product in Indoor Lighting .Such as :
LED Panel Light , Track Light , Linear Light ,Wall Light , LED Strip Light , LED Tube Light , Cabinet Light , LED Bulb , LED Ceiling Light as so on .
Recessed Downlight,LED Recessed Downlight,Halo Ultra Thin Downlight,Surface Mounted Downlight
JIANGMEN LEDERLIGHT LIGHTING Co.,LTD , https://www.poollightsled.com